INTELLICHEM
®
Controller Installation and User’s Guide
22
Chlorinator: This screen displays the current IntelliChlor (SCG) status, salt (ppm) levels
and error conditions. The hexadecimal status value is decoded and displayed in the
brackets on the bottom line; multiple error conditions are shown by sequencing through the
messages.
This display can be used to determine if the SCG is connected and responding to the
IntelliChem. If the IntelliChlor is connected, this display may show “Please wait 2-7 minutes
for ppm”. This indicates the IntelliChlor is responding to initial contact but until water flow
and sufficient salt level is reached, the IntelliChlor will not respond with further information
like salt ppm and status. Sometimes it is helpful to cycle power on the IntelliChlor and wait
10 minutes for the green lights before it will respond with ppm and status information; it
may not respond if the Salt or Cell lights are flashing red.
If the Configuration / Hardware / ORP Control / Doser Type is set to IntelliChlor, the
IntelliChem will control the IntelliChlor as it would a doser, actively turning it on (100%) for
chlorine demand, and off (0%) when the ORP reaches the desired set point.
For the Chlorinator to work when connected to an Automation controller like the
IntelliTouch, EasyTouch, or SunTouch, those units must be configured with the IntelliChlor
enabled. The displays is as follow:
Diagnostics (Continued)
Configuration Menu (Continued)