IntelliFlo VF Installation and User’s Guide
31
""""
2222
1).
u
Note:
NAME VALUE DESCRIPTION
Clean Filter
Pressure
0,1 to 3,5 bar
(default 1.0 bar)
The dierential pressure from the 0-pressure to 100% lter
status.
Turnovers
Per Day
1-8 (Default 1)
The number of times per day the volume of water setup in
“Pool Volume” will be moved.
Cycles per
Day
1-4 Cycles (Default 1)
The number of cycles (start and stop) the IntelliFlo must do
per day.
Start Cycle 1
1:00 -12:59 HH.MM am/pm
(Default 9:00)
Start time for cycle 1 (if start and stop is the same time the
IntelliFlo will run 24*7).
Stop Cycle 1
1:00 -12:59 HH.MM am/pm
(Default 21:00)
Stop time for cycle 1 (if start and stop is the same time the
IntelliFlo will run 24*7).
Start Cycle 2
1:00 -12:59 HH.MM am/pm
(Default 21:10)
Start time for cycle 2. If “Cycles per day” is below 2, “Dis-
abled” will be displayed.
Stop Cycle 2
1:00 -12:59 HH.MM am/pm
(Default 21:20)
Stop time for cycle 2. If “Cycles per day” is below 2, “Dis-
abled” will be displayed.
Start Cycle 3
1:00 -12:59 HH.MM am/pm
(Default 21:30)
Start time for cycle 3. If “Cycles per day” is below 3, “Dis-
abled” will be displayed.
Stop Cycle 3
1:00 -12:59 HH.MM am/pm
(Default 21:40)
Stop time for cycle 3. If “Cycles per day” is below 3, “Dis-
abled” will be displayed.
Start Cycle 4
1:00 -12:59 HH.MM am/pm
(Default 21:50)
Start time for cycle 4. If “Cycles per day” is below 4, “Dis-
abled” will be displayed.
Stop Cycle 4
1:00 -12:59 HH.MM am/pm
(Default 22:00)
Stop time for cycle 4. If “Cycles per day” is below 4, “Dis-
abled” will be displayed.
Filter Menu (Continued)
Filter Cycle Settings