37
IntelliFlo VF Installation and User’s Guide
Features Menu (Continued)
Features Settings
Name Value Description
F1-9, M.O. Flo
Set Flow
4-29m
3
/h
(Default 12m
3
/h)
Programs the rate of ow for feature 1 - 10
F3-9, M.O. Flo, Wave, Pulse
Activation
Enabled / Disabled
(Default Disabled)
When this setting is set to Enabled, the feature activates at the time specied
in the “Set Start Time” setting. If this setting is set to Disabled, the feature does
not activate.
F1-2:
Time Duration
1 minute - 10 Hours, or 00:01 - 10:00
(Default 00:01)
Sets the length of time for which Feature 1 or 2 will operate.
Time duration must be selected for Feature 1 and 2.
F3:
Set Start time
00:00 - 23:59
Default 06:00 am)
Sets start time for feature 3
F3:
Stop time
00:00 - 23:59
(Default 06:10)
Sets stop time for feature 3
F4:
Start time
00:00 - 23:59
(Default 06:20)
Sets start time for feature 4
F4:
Stop time
00:00 - 23:59
(Default 06:30 am)
Sets stop time for feature 4
F5:
Start time
00:00 - 23:59
(Default 06:40)
Sets start time for feature 5
F5:
Stop time
00:00 - 23:59
(Default 06:50 am)
Sets stop time for feature 5
F6:
Start time
00:00 - 23:59
(Default 07:00)
Sets start time for feature 6
F6:
Stop time
00:00 - 23:59
(Default 07:10 am)
Sets stop time for feature 6
F7:
Start time
00:00 - 23:59
(Default 07:20)
Sets start time for feature 7
F7:
Stop time
00:00 - 23:59
(Default 07:30)
Sets stop time for feature 7
F8:
Start time
00:00 AM - 23:59
(Default 07:40)
Sets start time for feature 8
F8:
Stop time
00:00 AM - 23:59
(Default 07:50)
Sets stop time for feature 8
F9:
Start time
00:00 AM - 23:59
(Default 08:00)
Sets start time for feature 9
F9:
Stop time
00:00 AM - 23:59
(Default 08:10)
Sets stop time for feature 9
M.O.Flo
Set Run time
1 - 59 minutes, or 00:01 - 00:59
(Default 00:01)
Sets the duration of time over which the M.O.Flo feature will operate the
pump at the intervals specied in the “Set Interval Time” setting, and at the
rate specied in the “Set Flow” setting
M.O.Flo
Set Interval time
2 - 255 minutes, or 00:02 - 04:15
(Default 60 minutes, or 01:00)
Sets the time between activations of the pump at the rate specied in the “Set
Flow” setting
Wave, Pulse
Feature Linked
1-9
(Wave Default 1, Pulse Default 2)
Refers to the feature to which the Wave or Pulse feature is linked
Wave, Pulse
Set Max Speed
450 - 3450 RPM
(Default 3450 RPM)
Sets the highest pump speed, in Rotations Per Minute (RPM), at which the
Wave or Pulse feature will operate
Wave, Pulse
Set Min Speed
400 - 3400 RPM
(Default 400 RPM)
Sets the lowest pump speed, in Rotations Per Minute (RPM), at which the Wave
or Pulse feature will operate
Wave, Pulse
Period
Wave 10 - 300 seconds or 0010 - 0300
(Default 0010)
Pulse 2 - 300 seconds or 0002 - 0300
(Default 0002)
For the Wave feature, this setting sets the length of time it takes for the pump
to transition between the values set in the “Max Speed” and “MIn Speed”
settings. For the Pulse feature, this setting determines the length of time the
pump will maintain a randomly generated speed between the values set in
the “Max Speed” and “Min Speed settings.