OPERATING THE PUMP 4/25
Disabled / Enabled - Default: Enabled
40° F - 50° F (4.4° C through 10° C) Default: 40° F (4.4° C)
Speed - Default: Speed
EXT CONTROL
THERMAL MODE
Stop Delay (0 min. to 10 min.) Default: 0 Minutes
Disabled/Enabled
Set Type
Pump Temperature
Program 1
Program 2
Program 3
Program 4
Quick Clean Duration (1 min. to 10 hrs.) Default: 10 minutes
Time Out Duration (1 min. to 10 hrs.) Default: 3 hours
FEATURES
Quick Clean
Time Out
(1 min. to 30 min.) Default: 11 minutes
(1 - 10) Default: 5
(1 sec. to 10 min.) Default: 20 seconds
PRIMING
Max Priming Duration
Priming Range
Priming Delay
Priming Speed
Set Speed (2400-3450 RPM) Default: 3450 RPM
Type (Speed / Flow) Default: Speed
Type (Speed / Flow)
Loss of Prime
Enabled / Disabled - Default: Enabled
Flow
Disabled / Enabled - Default: Enabled
Disabled/Enabled
Set Speed/Flow
Set Speed (450-3450 RPM) Default 1000 RPM
Set Flow (5.5 - 38 m³/h) Default: 11 m³/h
MENU TREE
CONTINUED FROM
PREVIOUS PAGE
Enabled - Default
Pump Off
Stop Delay (0 min. to 10 min.) Default: 0 Minutes
Type (Speed / Flow) Default: Speed
Enabled - Default
Pump Off
Stop Delay (0 min. to 10 min.) Default: 0 Minutes
Type (Speed / Flow) Default: Speed
Enabled - Default
Pump Off
Stop Delay (0 min. to 10 min.) Default: 0 Minutes
Type (Speed / Flow) Default: Speed
Enabled - Default
Pump Off
Set Speed or Flow - Default: 750 RPM
Set Speed or Flow - Default: 1500 RPM
Set Speed or Flow - Default: 2350 RPM
Set Speed or Flow - Default: 3110 RPM
Set Speed or Flow (450-3450 RPM or 5.5-38 m³/h)