Troubleshooting Guide (Continued)
Symptom Cause Remedy
Pressure tank too small. Fit a larger capacity or
secondary pressure tank.
Pressure tank has incorrect
air charge.
Check pressure with tyre
gauge or similar. Adjust
pressure to 10% below the
cut-in pressure of the pump.
Pressure switch setting
incorrect.
Have your local pump
professional adjust the
pressure switch and tank
pressure accordingly.
Rapid Cycling.
Pump injector combination
too large for application.
Consult your local pump
professional to ascertain the
correct injector for your
application.
Should problems persist, contact your nearest Onga service agent.