Model Data - JJ400, JJ600, OJ700 & OJ800
Technical Data
Voltage 230V / 415V
Motor Watts 750W (JJ400); 1800W (JJ600)
1800W (OJ700); 3000W (OJ800)
Suction / Discharge Refer Product Guide.
IP Rating
IP44
Motor Frequency 50Hz
Water temperature range 2 - 40
o
C
Maximum ambient temperature 40
o
C (for effective motor cooling
ensure the ambient temperature
does not exceed 40
o
C).
Incorrectly installed or tested equipment may fail,
causing severe injury or property damage.
Pump
Model
Supply
voltage
Phase
Nominal
Horsepower
Motor
input
power
(P
1
)
Starting
current
(Amps)
Full Load
current
(Amps)
Power
Supply
Lead
(Amps)
Outlet
(BSP)
JJ400 230 1 1 1 19 4.6 10A 3/4' F
JJ600 230 1 1.1/2 1.6 31.4 7.7 10A 3/4' F
JJ600 415 3 2.1/2 2.451 25 2.9 N/A 3/4' F
OJ700 230 1 2.1/2 2.61 47.5 8.9 10A 1' F
OJ700 415 3 2.1/2 2.451 25 3.6 N/A 1' F
OJ800 230 / 480 1 3.3/4 3.569 71.2 14 / 7 15A 1' F
OJ800 415 3 3.3/4 3.569 38.69 5.5 N/A 1' F