IMPORTANT: Before installing this reverse osmosis system,
make certain your water supply complies with the following
operating specifications. Failure to do so may reduce the
effectiveness of the system and will void the warranty.
SPECIFICATIONS
Thin Film Membrane: TFM-50
Feed Water Pressure: 40 to 100 psi (2.75–6.9 bar)
Temperature Range: 40–100°F (4.4–37.7°C)
TDS: 2000 ppm
Maximum Hardness
†
: 10 gpg (171 mg/L)
Sulfide, Iron and Manganese
‡
: 0 ppm <0.1 ppm
Chlorine in Water Supply: Less than 2 ppm
pH Limits: 3–11
Daily Product Water Rate: 15.04 gpd (56.93 Lpd)
TDS Rejection: 96.2%
Turbidity: 11 NTU Average
†
If the hardness of your water is above 10 gpg (171 mg/L), lime
scale will build up rapidly on the membrane. Scale buildup will
plug the membrane and make the system ineffective. We do not
recommend these reverse osmosis systems to be used with
water in excess of 10 gpg (171 mg/L) hardness.
‡
A maximum total level of approximately 0.01 ppm sulfide, iron
or manganese is permissible. See your local dealer to reduce
these substances in your water.
PRODUCTION CAPABILITIES
Tested by NSF International according to NSF/ANSI Standard 58
has given 15.04 gallons per day. Source water test parameters
are 50 psig, 77°F, pH of 7.5 ± 0.5 and 750 ppm total dissolved
solids.
PARTS INCLUDED: (SEE BACK OF MANUAL FOR DIAGRAM)
Pre-assembled filter system (mounting bracket, membrane
housing, membrane, pre- and post-filter housings and pre-
and post-filter cartridges).
• Reverseosmosismembrane •Storagetank
• Inletsupplyadapter •Chromefaucet
• Drainclamp •Feedtubing
• 1/4-inchTubing •Sumpwrenches
• Tankvalve •3/8-inchTubing
SYSTEM DIMENSIONS:
Overall Dimensions: 13
1
⁄2-inch W x 5
1
⁄2-inch D x 17
1
⁄4-inch H
(34.29cmWx12.7cmDx43.8cmH)
Weight: 17.3lbs.(7.84kg)
Tank Dimensions: 13
1
⁄2-inch W x 9 inch D x 9 inch H
(34.29cmWx22.86cmDx22.86cmH)
TankCapacityMax: 2.8gal.(10.6L)
TankAirPressureEmpty: 5to7psi(0.34to0.48bar)
TankWeight(Full): 28.5lbs.(12.9kg)
INSTALLATION
The RO-2550 is Tested and Certified by NSF International
againstNSF/ANSIStandard58forthereductionofTotal
Disolved Solids, Fluoride, Turbidity, Lead, Selenium,
Copper and Cysts.
Tools and Materials Required
• Hand or electric drill
(cordless preferred)
• (2) Adjustable wrenches
• Slotted and Phillips screwdrivers
• File
• Safety glasses
• Drillbits:1/8",3/16",1/4",3/8"
If sink does not have hole for separate faucet:
• Center punch
• Cone-shaped grinding wheel
• 1-1⁄4"holesawordrillbit
• Safety mask
NOTE: All tools may not be necessary for installation. Read
installation procedures before starting to determine
what tools are necessary.
2•Pentek
®