(A) To prevent leaks, apply 3 or more wraps of plumber tape to threads on tank.
Thread the tank valve onto the top of the tank opening. Turn tank so handle is
in line with tubing.
The tank/valve connection will leak if not properly sealed. plumber tape
will normally seal the threaded connection.
(B) Locatethe1/4-inchtubing.Placeamarkonthetubing5/8-inchfromeach
end. Moisten one end of the tubing with water and insert with a twisting
motionintotheportofthetankvalveuntilthe5/8-inchmarkisflushwiththe
quick connect fitting. Then locate the tank near the system's installation area.
(C) Cut the tubing to correct length. Install free end of tubing into white quick-
connect fitting on the post filter tee on the right side. Do not cut tubing.
(D) Place entire system over mounting screws on wall and slide down.
Make certain system is firmly attached to wall to prevent it from falling
and possibly becoming damaged.
NOTE: Use caution not to bend or pinch the tubing behind the system while
attaching to mounting screws.
9. Connecting the Supply Adapter and Inlet Filter
(A) Locate remaining length of 1/4-inch plastic tubing.
(B) Push into quick connect fitting on the right side of system.
(C) Cut the tube to a length that will allow connection to the cold water supply
fitting. Ensure the tubing does not kink. Push the tube into the fitting.
10. Installing the Membrane
(A) Remove tube attached to membrane housing by pressing in the white collar
around the fitting while pulling the tubing with your other hand.
(B) Hold the membrane housing with one hand and turn the cap (wrench
provided) with other hand to remove. To make it easier to hold the membrane
housing, you may want to remove the post-filter.
(C) With clean hands (sanitary gloves preferred), remove the membrane from the
plastic bag. HANDLE WITH CARE.
Do not unwrap the tape around the membrane, as it is part of the
membrane. Do not squeeze membrane.
(D) With the double O-ring side first, push membrane into housing until it stops.
About1/8-inchofthemembrane’splasticcorewillstickoutbeyondthe
housing.
(E) Use clean silicone grease (pack is included with the system) to lubricate both
O-rings and the brine seal. Hand-tighten membrane housing cap until you feel
resistance, then tighten an additional 1/2 turn. Do not over-tighten.
(F) Reinsert the tube by pushing it into the quick connect fitting.
INSTALLATION CONTINUED . . .
11. Faucet Operation
(A) For controlled water flow, push the handle down.
B
Port Reference
9
A
C
1/4"Tube
5/8"
16 mm
5/8"
16 mm
10
A
A
D
E
Port Reference
Port Reference
C
8
A
B
1/4"Tube
Apply
plumber
tape
5/8"
6•Pentek
®