35
SunTouch Pool and Spa Control System Installation and Users Guide
Note: (*) "SOLAR ONLY" menus see page 6.
Filter Pump: [On/Off] - Default Off - see page 13
AUX 1, AUX 2, AUX 3 [On/Off]
Circuit On/Off 1/13
LOW TEMP [40˚ F - 104˚ F] or [4˚ C - 40˚ C] - see page 14.
LOW HEAT [Off/Heater/Solar Prf/Solar] - To display "Solar Prf/Solar" selections, enable Solar in Solar menu.
HIGH TEMP [40˚ F - 104˚ F] or [4˚ C - 40˚ C] - see page 14
HIGH HEAT [Off/Heater/Solar Prf/Solar] - To display "Solar Prf/Solar" selections, enable Solar in Solar menu.
Manual Heat: [ON / OFF] - Default Off - See page 15
Heat 2/13
[Delayed Cancelled] Press Right button to cancel delays. - see page 16
Delay Cancel 3/13
Schedules: [LOW / HIGH / AUX 1 / AUX 2 / AUX 3] - see page 17
Program: 4/4 [Add, Edit, Skip, Delete]
Schedule: Start/Stop [08:00A - 05:00P] 12:00 AM - 11:59 PM - 12 Hours
Schedules 4/13
Time Set: 06:00 AM [Hour/Minutes - AM/PM] - see page 19
Clock 5/13
Solar Status: Enabled [NO / YES] - Default Off - see page 20
Start Temp Diff: Temp Diff [6 %]
Stop Temp Diff: Temp Diff [3 %]
Heat Pump: [Yes/No] - Default No
Solar 6/13
Advanced 8/13
Heater Delay: [No / Yes] - See page 22
Temp Units: [FAHRENHEIT / CELSIUS]
Calibrate Water: Temp 10˚ F
Calibrate Air: Temp 90˚ F
Calibrate Solar: Temp 100˚ F
Air Sensor: [On/Off] - Default On
System Mode: [Pool/Spa/Solar Only*]
System Type: [Shared Equipment, Single Body]
Reset Factory: [Erase ALL? (No / Yes]
Valves Circuit: [NONE, HIGH, LOW, AUX 1, AUX 2, AUX3, SOLAR, HEATER, FREEZE] - see page 21
Valves 7/13
Firmware Rev (System firmware revision level) - see page 25
Solar Temp [Fahrenheit/Celcius - Status display only] - (Displays if Solar is enabled in Heat menu)
Self Test
Diagnostics 9/13
SINGLE SPEED [TWO SPEED, INTELLIFLO 4] - see page 29
Two Speed - Pump Circuits 1 - 4 [None, HIGH, LOW, AUX 1, AUX 2, AUX 3, Solar Heater, Pool Heater, Spa Heater, Freeze]
IntelliFlo 4 - Circuit 1 - 4 - Set pump speed
1 - RPM: [400-3450] - 750 Default
1 - Pump Circuit - [None, HIGH, LOW, AUX 1, AUX 2, AUX 3, Solar Heater, Pool Heater, Spa Heater, Freeze]
2 - RPM: [400-3450] - 1500 Default
2 - Circuit - [None, HIGH, LOW, AUX 1, AUX 2, AUX 3, Solar, Heater, Freeze]
3 - RPM: [400-3450] - 2350 Default
3 - Circuit - [None, HIGH, LOW, AUX 1, AUX 2, AUX 3, Solar, Heater, Freeze]
4 - RPM: [400-3450] - 3110 Default
4 - Circuit - [None, HIGH, LOW, AUX 1, AUX 2, AUX 3, Solar, Heater, Freeze]
Pumps 12/13
QuickTouch 11/13
QuickTouch - Assign 1 - 4 circuits) - see page 28
1, 2, 3, 4 [None, HIGH, LOW, AUX 1, AUX 2, AUX 3, Solar, Heat Boost, Heat Enabled]
LOW Circuit: Freeze [OFF / ON] - see page 26
HIGH Circuit: Freeze [OFF / ON]
AUX 1 Circuit: [Generic, Solar, Floor Cleaner, Spillway, Cleaner] - Freeze [OFF / ON]
AUX 2 Circuit: [Generic, Solar, Floor Cleaner, Spillway, Cleaner] - Freeze [OFF / ON]
AUX 3 Circuit: [Generic, Solar, Floor Cleaner, Spillway, Cleaner] - Freeze [OFF / ON]
Circ. Functions 10/13
IntelliChlor: Enable [No / Yes] - see page 31
Pool %: (0% - 100%) - 50 (Default)
Spa %: (0% - 100%) - 8 (Default)
Super Chlr: (No/Yes) - No (Default)
Run Hours: (0 -72) - 0 (Default)
IntelliChlor - Salt Level: Displays current salt level (xxxx) ppm - Status: OK - NO ERRORS
(SUPER CHLORINATE, COM LINK ERROR, CHECK FLOW / PCB, LOW SALT, VERY LOW SALT,
HIGH CURRENT, CLEAN CELL!!, LOW VOLTAGE)
IntelliChlor 13/13