8
Troubleshoong
Use the following troubleshoong informaon to resolve possible problems with the SC-75 Salt Chlorinator Power Center.
Note: Switch power o to unit before to aempng service or repair. Always remove AC power to Power Center when plugging
or unplugging the SC-75 cell into the Power Center.
Problem Possible Cause Correcve Acon
SC-75 Cell leds are not on. Fuse in Power Center is open/broken. Replace 8AMP fuse, located at boom of
Power Center.
No AC power to Power Center. Verify me clock is providing 220VAC to Power
Center when acve.
Transformer leads not wired correctly in
Power Center.
Verify transformer leads wired to AC source by
referring to wiring diagram decal on inside of
Power Center cover.
Limited Warranty : 2 years
More info : www.pentairpooleurope.com
System Specicaons - 230 VAC
Circuit Protecon: Two pole 20AMP devise at the electrical panel.
Model SC-75P (Power Centre)
Input: 50Hz, 220-240 VAC, 220W, 1 Amp. Output: 28 VAC @ 5.2 Amp Max.
Water ow: 6m³/h (25GPM) - Max ow: 24m³/h (105GPM) - Max Pressure: 5Bar (75PSI)
SC-75 AC Wiring Instrucons :
- When using the SC-75 Salt Chlorinator and an IntelliFlo pump (or variable speed pump) with a Pentair IntelliPool Automaon
System, please read the IntelliPool installaon manual - Secon ‘Desinfectant Connecon - Alternave Salt Chlorinator.
- When using the SC-75 Salt Chlorinator with the ‘Pentair ControlPro Filtraon Manager’ and a Variable Speed pump, please
read the ‘Pentair ControPro Filtraon Manager’ installaon manual.