14
ThermalFlo Installation and User’s Guide
Connecting the ThermalFlo to the IntelliTouch or EasyTouch Load Center
To connect the ThermalFlo cable to the Personality Board in the IntelliTouch or EasyTouch Load Center:
1. Turn off the main system power before making any connections.
2. Unlatch the front door spring latche(s), and open the front door of the IntelliTouch or EasyTouch Load Center.
3. Loosen the two retaining screws from the top of the control panel and lower the control panel down
to access the Personality Board.
4. Run a UL approved conductor cable from the ThermalFlo to the Load Center.
5. Route the cable up through the low voltage raceway located on the left of the Load Center to the
Personality Board, see Figure 13.
6. Insert the ThermalFlo cable plug onto the gas heater terminal connector located
on the left side of the Personality Board.
7. If the heat pump is used in conjunction with a gas heater, use a 52043 Dual Heater Relay Kit. Plug the
heat pump relay connector onto the SOLAR Terminal on the top center of the Personality Board.
Follow Dual Heater Relay Kit instructions for further set-up details.
8. Lift the control panel up into position and secure with the two screws.
9. Connect the cable from the IntelliTouch or EasyTouch Load Center to the heat pump remote control
terminals using 1/4 inch “Fast-On” Spade connectors, see Figure 12, previous page.
Figure 13.
new page 14 5/17/06 4:25 PM Page 1