EasyManua.ls Logo

Pentair TRITON - Section 4 Filtration; Section 5 To Clean (Backwash) the Filter; Section 6 Servicing and Maintenance; Replacement of Sand

Pentair TRITON
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 2
Installation
Install the lter in a dry, well-ventilated location with adequate access for servicing. Place the lter in its permanent location on a
completely level base, preferably made of concrete poured as a single slab or on a platform constructed of concrete blocks or bricks.
Pipes should preferably be made of PVC. Set the suction pipe at a slight angle to avoid the formation of air bubbles. Fit the valve
(follow drawings at the end of this manual) and position the lter in the correct place. Make sure that the valve on the lter can be
easily accessed. Then t the plumbing.
Triton® : Fit pressure gauge and T-adaptor to cap.
Section 3
Operation
Before pouring media, look inside and check lower underdrain for broken ore loose laterals. The sand is put in through the opening
in the top of the lter.
Triton® : Turn the top diffuser system sideways until it clicks tight. Fill the tank 1/3 full with water. Protect the thread on the lter by
covering it with adhesive tape. Next ll the lter with the specied amount of gravel and then sand. Do this carefully to avoid damag-
ing the bottom laterals. After lling, turn the top diffuser pipe back to its original vertical and centered position so that it again clicks into
position. Remove the adhesive tape and clean the thread. Pull the air relief tubing slightly upwards, so the breather pipe strainer will
t into the cap after the cap has been tted. Place the O-ring seal on the cap and tighten hand-tight with wrench. Shift valve handle
to “Rinse” position. Now start the pump and open the bleed valve until water begins to appear from the blow-off opening in the bleed
valve.
Tagelus® : Fill tank for 1/3 with water. Before lling the lter, sand guide should be on the pipe. Fill the lter with the specied quantity
of gravel, afterwards with sand. Remove the sand guide. Assemble the valve to the lter and tighten with the clamp ring. Connect the
piping. Turn the valve into position “Rinse” and start the pump for at least 1 minute.
Never shift valve handle position while pump is running
Section 4
Filtration
When the lter is used for the rst time, shift the valve handle to ‘Rinse’ position, until you see clear water appearing through the
sideglass (Triton®). Then continue with step 1 till 5:
1. Shift multi-port valve handle to “Filtration” position.
2. Start the pump.
3. Bleed off any air in the lter.
4. Filter is running.
5. Make a note here of the pressure showing on the pressure gauge: bar.
Section 5
To clean (backwash) the lter
When the pressure has increased by 0.5 bar or more (the measurement registered above) the lter sand needs to be backwashed.
This is done as follows:
1. Shut off the pump.
2. Shift the valve handle to “Filter backwash”.
3. Start pump and let it run until water is clean (Triton®: about 5-10 minutes; Tagelus®: about 3 minutes).
4. Shut off the pump and turn off the water supply to the pump.
5. Clean the basket of the pump and turn on the water supply to the pump after closing the cleaning strainer cap.
6. Shift valve handle to “Rinse” position.
7. Start pump and run for approximately one minute.
8. Shut off the pump.
9. Shift valve handle to position “ltration” and start the pump.
Section 6
Servicing and Maintenance
Proper care and maintenance will add many years of service and enjoyment to the pool. To clean lter exterior of dust, dirt, wash with
a mild detergent and water, then hose off. Never wash the transparent cap with a solvent as it may become cloudy.