EasyManua.ls Logo

Pentair ULTRATEMP - General Installation Information; General Specifications

Pentair ULTRATEMP
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
vi
Installation and Users Guide
IMPORTANT SAFETY PRECAUTIONS (continued)
General Installation Information
1. Installation and service must be performed by a qualified installer or service agency, and must conform to all
national, state, and local codes.
2. UltraTemp
®
heat pumps get electrical power from an external source and provide a dual electronic thermostat
control system for pool/spa combinations or preheat convenience.
3. This heat pump is specifically designed for heating fresh water swimming pools and spas. Do not use it as a
general service heater. Consult your dealer for the appropriate Pentair Water products for these applications.
General Specifications
Installation Location Certified for use:
OUTDOOR USE ONLY.
Failure to provide the proper clearances outlined on page 5 will lower the
performance of the heat pump and void the warranty.
Water Pipe/Heater Connection — Plastic 2” PVC (Unions included)
Flow Rate
Maximum 100 gpm [380 lpm]
Minimum 30 gpm [110 lpm]
Maximum Working Water Pressure 50 psi
Electrical Supply – Voltage Requirements:
110 120 120 H/C 120C 100I 90I
Voltage/Phase/Hz
208-230/1/60 208-230/1/60 208-230/1/60 208-230/3/60 230/3/60 380-400/3/50
Min. Circuit Ampacity
42 42 42 35 42 18
Recommended Fuse Size
50 50 50 50 50 30
Max. Fuse Breaker Size
70 70 70 60 60 40
Compressor/Fan Motor/System RLA
32/2/34 32/2/34 32/2/34 26/2/28 32/2/34 12/1/13
Compressor/Fan Motor/System LRA
148/4/152 185/4/189 185/4/189 190/4/194 130/4/134 87/3/90
Compressor/Fan Motor/System MCC
50/NA/NA 50/NA/NA 50/NA/NA 39/NA/NA 50/NA/NA 19/NA/NA
Capacity (Btu/h) 80A-80RH-80W * 108,000 125,000 125,000 125,000 102,000 85,000
COP 80A-80RH-80W * 5.8 5.5 5.4 6.1 5.9 5.7
Power Input, KW (80A-80RH-80W) * 5.5 6.7 6.8 6.0 5.1 4.4
Current, Amp (80A-80RH-80W) * 25 30 31 19 25 9
Capacity (Btu/h) 80A-63RH-80W ** 101,000 117,000 117,000 115,000 96,000 81,000
COP 80A-63RH-80W ** 5.5 5.3 5.2 5.8 5.6 5.4
Power Input, KW (80A-63RH-80W) * 5.4 6.5 6.6 5.8 5.0 4.4
Current, Amp (80A-63RH-80W) * 25 29 30 18 24 9
Capacity (Btu/h) 50A-63RH-80W *** 72,000 82,000 82,000 81,000 67,000 56,000
COP 50A-63RH-80W *** 4.0 4.0 4.0 4.3 4.0 4.0
Power Input, KW (50A-63RH-80W) * 5.3 6.0 6.0 5.5 4.9 4.1
Current, Amp (50A-63RH-80W) * 24 27 27 17 24 9
Shipping Weight (lbs) 270 270 278 280 280 250
Shipping Size (LxWxH) 38.7"x33.3"x45.5" 38.7"x33.3"x45.5" 38.7"x33.3"x45.5" 38.7"x33.3"x45.5" 38.7"x33.3"x41.5" 38.7"x33.3"x33.5"
* 80A-80RH-80W: 80° F. Air Temp., 80% Relative Humidity [RH], 80° F. Water Inlet Temp.
** 80A-63RH-80W: 80° F. Air Temp., 63% Relative Humidity [RH], 80° F. Water Inlet Temp.
*** 50A-63RH-80W: 50° F. Air Temp., 63% Relative Humidity [RH], 80° F. Water Inlet Temp.
COP = Coefficient of Performance
Models
UltraTemp
®

Table of Contents

Other manuals for Pentair ULTRATEMP