vi
Installation and User’s Guide
IMPORTANT SAFETY PRECAUTIONS (continued)
General Installation Information
1. Installation and service must be performed by a qualified installer or service agency, and must conform to all
national, state, and local codes.
2. UltraTemp
®
heat pumps get electrical power from an external source and provide a dual electronic thermostat
control system for pool/spa combinations or preheat convenience.
3. This heat pump is specifically designed for heating fresh water swimming pools and spas. Do not use it as a
general service heater. Consult your dealer for the appropriate Pentair Water products for these applications.
General Specifications
Installation Location Certified for use:
OUTDOOR USE ONLY.
Failure to provide the proper clearances outlined on page 5 will lower the
performance of the heat pump and void the warranty.
Water Pipe/Heater Connection — Plastic 2” PVC (Unions included)
Flow Rate
Maximum 100 gpm [380 lpm]
Minimum 30 gpm [110 lpm]
Maximum Working Water Pressure 50 psi
Electrical Supply – Voltage Requirements:
110 120 120 H/C 120C 100I 90I
Voltage/Phase/Hz
208-230/1/60 208-230/1/60 208-230/1/60 208-230/3/60 230/3/60 380-400/3/50
Min. Circuit Ampacity
42 42 42 35 42 18
Recommended Fuse Size
50 50 50 50 50 30
Max. Fuse Breaker Size
70 70 70 60 60 40
Compressor/Fan Motor/System RLA
32/2/34 32/2/34 32/2/34 26/2/28 32/2/34 12/1/13
Compressor/Fan Motor/System LRA
148/4/152 185/4/189 185/4/189 190/4/194 130/4/134 87/3/90
Compressor/Fan Motor/System MCC
50/NA/NA 50/NA/NA 50/NA/NA 39/NA/NA 50/NA/NA 19/NA/NA
Capacity (Btu/h) 80A-80RH-80W * 108,000 125,000 125,000 125,000 102,000 85,000
COP 80A-80RH-80W * 5.8 5.5 5.4 6.1 5.9 5.7
Power Input, KW (80A-80RH-80W) * 5.5 6.7 6.8 6.0 5.1 4.4
Current, Amp (80A-80RH-80W) * 25 30 31 19 25 9
Capacity (Btu/h) 80A-63RH-80W ** 101,000 117,000 117,000 115,000 96,000 81,000
COP 80A-63RH-80W ** 5.5 5.3 5.2 5.8 5.6 5.4
Power Input, KW (80A-63RH-80W) * 5.4 6.5 6.6 5.8 5.0 4.4
Current, Amp (80A-63RH-80W) * 25 29 30 18 24 9
Capacity (Btu/h) 50A-63RH-80W *** 72,000 82,000 82,000 81,000 67,000 56,000
COP 50A-63RH-80W *** 4.0 4.0 4.0 4.3 4.0 4.0
Power Input, KW (50A-63RH-80W) * 5.3 6.0 6.0 5.5 4.9 4.1
Current, Amp (50A-63RH-80W) * 24 27 27 17 24 9
Shipping Weight (lbs) 270 270 278 280 280 250
Shipping Size (LxWxH) 38.7"x33.3"x45.5" 38.7"x33.3"x45.5" 38.7"x33.3"x45.5" 38.7"x33.3"x45.5" 38.7"x33.3"x41.5" 38.7"x33.3"x33.5"
* 80A-80RH-80W: 80° F. Air Temp., 80% Relative Humidity [RH], 80° F. Water Inlet Temp.
** 80A-63RH-80W: 80° F. Air Temp., 63% Relative Humidity [RH], 80° F. Water Inlet Temp.
*** 50A-63RH-80W: 50° F. Air Temp., 63% Relative Humidity [RH], 80° F. Water Inlet Temp.
COP = Coefficient of Performance
Models
UltraTemp
®