FOR TANK WITH GREY DRAIN ASSEMBLY
10. Thread grey drain into bottom of tank.
11. Connect all plumbing lines.
FILTRATION & PROCESS AIR CELL REPLACEMENT INSTRUCTIONS
Figure 3 - Drain Assembly
FOR TANK WITH BLACK DRAIN ASSEMBLY
10. Press the drain fitting into the bottom of the tank until it is
fully seated.
11. Install (2) large red C-clips into drain. The clips should snap
easily into place and should not be forced.
12. Press black threaded plumbing connection into the open end
of the drain. Press until fully seated.
13. Install (1) smaller red H-clip, securing the plumbing
connection to the drain.
14. Connect all plumbing lines.