Turn the rear e-dial (
..
#~~-)to
adjust the aperture value.
Press the
@ button to retain the shutter speed at 1/180 second and
automatically adjust the aperture value.
The sensitivity cannot be set to [ISO AUTO]
in
X mode. If the exposure
mode
is
changed to X mode when the sensitivity
is
set to [ISO AUTO], the
sensitivity is also changed to the lowest value set
in
"Setting the Range
of
Automatic Sensitivity Correction" (p.84
).
Selecting the Metering Method
Choose the part
of
the viewfinder to use for measuring brightness and
determining exposure. The following three methods are available. The
factory default setting is
~
(Multi-segment metering).
1
Turn
the
metering
mode
switch.
The set metering method
is
displayed
in
the status screen and viewfinder.
~
Multi-segmented Metering
The scene
in
the viewfinder
is
metered
in
77 different zones. Even
in
backlit
locations, this mode automatically
determines what level of brightness is
in
which portion and automatically adjusts
exposure.
~
Center-weighted Metering
Metering
is
weighted at the center of the
viewfinder. Use this metering when you
want to compensate for the exposure by
experience, instead
of
leaving it to the
camera. The illustration shows that
sensitivity increases as the pattern height
increases (center). This mode does not
automatically compensate for backlit scenes.