5-
9.
0- MlOl
(CCD
block)
( Required equipment )
Hexagonal
driver
1.5
mm
Amrnging
the
flexible
board
ofO
- MlOl,
instal
l
0-MlOl.
M104
x3
(CCD
block
spring),
W65
(t=0.5)
x3
Ml03
x3
(CCD
block
adjusting
screw)
[ Adjustment ]
CCD
block
temporary
pos
iti
on
Screw in
each
Ml03
until
it
stops,
then
screw
back
1
or
1
.5
tums.
*
App
ly super-glue
to
between the
head
ofM103
and
W65
after adjusting the
pos
iti
on
by
using
a
computer.
5-
10.
S300
(AF
motor
block)
-
1.
Install surely the power-
zoom
pins
of
S300
to
the
housing,
and
anange the lead wires
and
flexible
board
as
shown
in
the
diagram
tight.
-
2.
S300,
2 screws
(apply
the screw-
lock
agent)
(
AdyConfirmation
)
AF
joint stroke
[ Required equipment ] Vemier
ca
lipers
1.
Set the
focus
mode
switch to
"AF".
Red
(80
mm)
2.
[
Confirmation
]
When
the
mount
l
ock
bu
tton
is
not pressed, the
AF
coupler
of
AF
motor
(S300)
should
project
from
the
mount
surface
by
1.3
mm
or
more.
3.
(
Confirmation
]
When
the
mount
locJc
button is pressed and released the mount
lock
pin
comes to
mount
surlace, the
AF
coupler sho
uld
not project out of mount s
urface.
[ Adjustment ] Turn
an
eccentric screw
on
O-
A121
Qoint
lever assy.),
and
apply
the screw-
lock
agent to the screw after
adjusting.
4.
Confinnation
]
When
the
mount
lock
button is pressed
and
released, the Joint lever (0-Al21)
"\
~'"'
5-11.
L2,
L3
(Fresnel lens, Pentaprism)
l~\.
should be
moved
smoothly.
-
1.
L3,
M8
x2,
BT(24x30)
Me
2 S
M
6
(
.
Ml~7
/
'-
--
- . crew
two
1 s
...
retamer screw)
equa
ll
y.
,
-.....
-3.
M17
(Dust prevention seal)
-4.
Insta
ll
M21
(
...
retainer
plate
h
olde
r) as
sho
wn
in
the
diagram
.
Mrs
L3
\
-
5.
Hook
M4
(Fresnel lens retainer plate)
int
o
M21,
and
then put
L2
on
M4.
-
6.
M22-
OOA
- H (Focus
adjusting
washer)
[
Adj/Confirmatio
n )
Viewfi
nder
focus
and
Parallax
[ Required equipment )
Collimato
r,
Focus
master lens
· Install the eyepiece (0-M301) temporaril
y.
[ Adjustment ]
Adjust
viewfinder
focus
by replacing Focus
adjusting washer
A-
H
(M22
-
00A
to
H)
.
Standard:
0 + 0.07
mm
( Adjustment ]
Adjust
parallax
(right/left)
by
turning
two
retainer
screws (Ml6),
and
apply
the screw-
lock
agent to Ml6 after adjusting.
Standard:
Right/Left
1 ° or less
Top/Bottom
1
50
' or less
27250
'