TPD1317e Chapter 7
Page 51
7.6 Battery and Starter Cables
(a) Batteries
There are two methods by which battery performance is commonly stated:-
BS3911 uses the current which can be maintained for 60 seconds, without the voltage of a nominal 12V
battery dropping below 8.4 volts, whilst at a temperature of -18
o
C.
SAE J537 is similar except that the current is only maintained for 30 seconds and the voltage is allowed
to fall to 7.2 volts.
Model Batteries for temperatures down to -5
o
C (23
o
F)
12 Volt 24 Volt
M300Ti
M265Ti
M225Ti
M215C
M185C
One battery - 520 Amps BS3911
or 800 Amps SAE J537
Two 12V batteries in series - each 315
Amps BS3911 or 535 Amps SAE J537
M135
M130C
Two 12V batteries in parallel - each 315
Amps BS3911 or 535 Amps SAE J537
M115T
M92B
One battery - 520 Amps BS3911 or 800
Amps SAE J537
Two 12V batteries in series - each 440
Amps BS3911
Batteries for temperatures down to -15
o
C (5
o
F)
M300Ti
M265Ti
M115T
M92
Two 12V batteries in parallel, each 520 Amps
BS3911 or 800 Amps SAE J537
Two 12V batteries in series, each 520
Amps BS3911 or 800 Amps SAE J537
M225Ti
M215C
M185C
M135
M130C
Two 12V batteries in parallel - each 315
Amps BS3911 or 535 Amps SAE J537
Two 12V batteries in series - each 315
Amps or 535 Amps SAE J537
Note: Where starting at temperatures below freezing is an important requirement, a 24 volt system is the
preferred choice.
(b) Starter Cables
Starter cables for 12 or 24 volt systems
*Maximum total
length
Cable size
metric
Nominal C.S.A.
Nominal resistance in
ohms
Approx. equivalent size
Metres Feet mm
2
in
2
Per metre Per foot
English
imperial
America
B&S SAE
5,6 19.00 61/1,13 61 0.0948 0,000293 0.0000890 61/.044 00
9,0 28.30 19/2,52 95 0.1470 0,000189 0.0000600 513/.018 000
* The length of all cables in the starter circuit (whether positive or negative), should be added together to give
the ‘Total Length’