Warning LED Pattern List
21 Slow Warn, Superfast Warn
22 All Singleflash, All Flicker
23 Alt. Double, ALT. Quad w/Post Pop
24 All Double, ALL. Quad w/Post Pop
25 Alt Double, Alt. Pre-Pop Quad, Alt. Quad w/Post
Pop, Alt Flicker
26 All Double, All Quintflash, All Quadflash w/Post
Pop, All Flicker
27 All Quadflash w/Post Pop, All Doubleflash, All
Flicker
28 Alt. Pre-Pop Triple, Alt. Doubleflash, Alt Flicker **
29 Alt. Pre-Pops, Alt. Flicker, Superfast Warn
30 Delta Omega, All. Double, All. Flicker
31 One Output Steady---Other Output Singleflash
32 One Output Steady---Other Output Short-Long
33 Warn Medium (Alt. Long Singleflash)
34 Alt. Short - Alt. Long
35 Cycle All
= These Patterns meet California Title 13 and SAE J595
specifications in Red and Blue versions of the model
ULB44.
1 Slow Warn *
2 Fast Warn
3 Superfast Warn
4 Warn Fade
5 Pre-Pop Warn
6 All Singleflash
7 Alt. Tripleflash
8 All Tripleflash
9 Alt. Quadflash w/Post Pop
10 All Quadflash w/Post Pop
11 Alt. Quintflash
12 All Quintflash
13 Alt. Pre-pop Quintflash
14 All Flicker
15 Alt. PSU Flicker
16 One Side Pop, Other Side Rapid Fire
17 One Side Rapid Fire, Other Pop
18 Comet 1
19 Comet 2
20 Delta Omega (Flash Rate Sweep)
* Default Pattern #1
** Default Pattern #2
If at anytime you would like to go directly to the Slow Warn (pattern #1), simply press, and
hold the pattern select button for approximately 3 seconds. When the LEDs flash once,
release the button and the light will be in the Slow Warn pattern.
If you would like to place the light back into the default pattern (Pattern 28: Alternating Pre-
Pop Triple, Alternating Doubleflash, Alternating Flicker), simply press and hold the pattern
select button until the LED’s flash twice (approx. 6 seconds). Then release the button and
the light should be in the default pattern.
Toggle Mode: Pressing and holding the pattern select button until the LED’s flash three
times (approx. 9 seconds) will toggle thesteady output” for patterns 31 and 32.
Indicator LED: Pressing and holding the pattern select button until the LEDs flash four times
(approx. 12 seconds) will disable or enable the indicator LED.
The
Starburst Phantom
®
will remember the pattern it was in when turned off and
display the same pattern when re-activated.
Once your
Starburst Phantom
Starburst PhantomStarburst Phantom
Starburst Phantom
®
is installed, please test all the patterns and options
to familiarize yourself with the various patterns and the operation of the buttons.