6.4 Humidity
•
Operating (non-condensing) - 5 to 90%
• Storage (non-condensing) - 5 to 95%
•
Shipping (non-condensing) - 5 to 95%
6.5 Altitude
•
Operating - 0 to 10,000 ft
• Storage - 0 to 35,000 ft
•
Shipping - 0 to 35,000 ft
6.6 Air pressure
• Operating - 700 to 1100 mbar
•
Storage - 300 to 1100 mbar
•
Shipping - 300 to 1100 mbar
6.7 Earth magnetic field
North Hemispheric
H=0, V=450, Z=0mG
South Hemispheric
H=0, V= -500, Z=0mG
Equatorial
H=0, V=0, Z=0mG
7. Regulatory Compliance
7.1 Worldwide regulatory -
International Regulatory Specification
COUNTRY DOMAIN
SAFETY / EMC / ERGONOMICS /
STANDARDS
DOCUMENTS
INTERNATIONAL Sa
IEC60950-1: 2001. Group -and national
differences of all countries listed in CB
Bulletin No. 107A
CB Report and CB certificate
Sa
European Low Voltage Directives
73/23/EEC and 93/68/EEC
Declaration of Conformity
European Electromagnetic Compatibility
Directive 89/336/EEC amended by the
directive 93/68/EEC. EN 55022:1998
Class B
EN 55024: 1998
EUROPE
E
EN 61000-3-2: 2000
Declaration of Conformity and
Full EMC/CE test report