Alignments
EN 21TPB1.1HU LA 6.
2010-Nov-05
6.4.2 Display option code overview
Blind SAM-mode is used to set a display option in the set, while
not having a picture:
1. To access the Blind SAM mode, the user must unplug any
board connected to the back-end board.
2. Cool start the set.
3. Press "062598 + MENU + Panel ID" on the RC command
to set up panel ID.
Table 6-3 Display option code overview
CTN_ALT BOM# Panel Type Panel ID
32HFL5662L/F7 LG LC320WXN-SCA1 105
37HFL5682L/F7 LG LC370WUN-SCC1 103
42HFL5682L/F7 LG LC420WUN-SCB1 104