If both ComPair and the Force electronic service manual are installed, all the
schematics and CBAs of the television set are available by clicking on the
appropriate hyperlink. Example: Measure the DC-voltage on capacitor C2568
(Schematic/Panel) at the Monocarrier. Click on the "Panel" hyperlink to
automatically show the CBA with a highlighted capacitor C2568.Click on the
"Schematic" hyperlink to automatically show the electronic position of the
highlighted capacitor.
How To Connect
1. First install the ComPair Browser software (see the Quick Reference Card for
installation instructions).
2. Connect the RS232 interface cable between a free serial (COM) port of your PC
and the PC connector (marked with "PC") of the ComPair interface.
3. Connect the AC power adapter to the supply connector (marked “POWER 9V
DC") on the ComPair interface.
4. Switch the ComPair interface OFF.
5. Switch the television set OFF (and remove the AC power).
6. Connect the ComPair interface cable between the connector on the rear side of
the ComPair interface (marked"I2C") and the ComPair connector on the mono
carrier (Connector0267).
7. Plug the AC power adapter in the AC power outlet and switch on the ComPair
interface. The green and red LEDs light up together. The red LED turns off after
approximately 1 second, while the green LED remains lit.
8. Start the ComPair program and read the "introduction" chapter.