EasyManua.ls Logo

Philips Allegiant LTC 8800 Series - User Selectable DIP Switch Settings for TC8816 A Data Receiver Modules Used in TC8802 Monitor Expansion Bays

Philips Allegiant LTC 8800 Series
91 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
42
User Selectable DIP Switch
Settings for TC8816A Data Receiver
Modules used in TC8802 Monitor
Expansion Bays
NOTE: AFTER CHANGING ANY OF THE
FOLLOWING SWITCHES, THE SYSTEM MUST BE
POWERED OFF AND ON BY THE TC8802 MAIN
POWER SWITCH.
TC8816A Data Receiver modules contain two 8
position DIP switches (S100 & S101). The functions
assigned to the upper DIP switch (S100) are
reserved and all settings should be left in the OFF
position. The options assigned to the 8 position DIP
switch S101 are as follows:
DIP Factory
Switch Default S101 DIP
Number Setting Switch Function
1 OFF Reserved
2 OFF Keyboard Group
3 ON Keyboard Group
4 OFF Reserved
5 OFF Reserved
6 OFF New Keyboard Mode
7 ON Operational Mode
8 OFF Operational Mode
Switch 1
This switch is reserved and should always be left off.
Switch 2 and Switch 3
Up to 8 system keyboards can be connected to the
rear panel of the TC8802 Monitor Expansion Bay.
DIP switches 2 and 3 determine the system keyboard
group that can be assigned to the TC8802 bay.
Follow the table below to select the desired group.
Switch 2 Switch 3 Keyboard Group
Off Off Reserved
Off On Keyboards 9-16
(Default)
On Off Keyboards 17-24
On On Keyboards 25-32
Switch 4 and Switch 5
These switches are reserved and should always be
left off.
Switch 6
When switch 6 is ON, the TC8816A Data Receiver
module will communicate with system keyboards
using a ‘6 poll byte’ protocol. This format is used to
provide variable speed pan/tilt control capability for
AutoDome equipped camera sites and is only
compatible with TC8550A, TC8551A, TC8553,
TC8554, and TC8555 type keyboards. The default
setting is OFF.
Switch 7
This switch determines the operational mode of the
TC8816A and must always be left on.
Switch 8
This switch determines the operational mode of the
TC8816A and must always be left off.

Table of Contents