Published by Philips Domestic Appliances Page 9 of 24 For internal use only
Document No. : CSW-07-081-21363
Disassembly Instruction
Before dismantling :
Ensure the plug is disconnected from the mains and Soleplate is not hot.
1
2
Remove BACKPLATE COVER 8
Remove 2x Screw A & remove BACKPLATE
MOLDED 9
3
4
Lift up PUMP COVER PRINTED 5 & remove it
Remove PUMP ASSY 15 and remove wire
Connections (applicable for Pump version only)
5
6
Open Filling Door & remove Rubber Bung
Remove Screw D
7
8
Loosen all wires, remove CLOSED END
CONNECTOR 16 & 17 (refer to page 15 for details)
Remove BALL SWIVEL 13