EasyManua.ls Logo

Philips HQ7180 - Service Manual

Philips HQ7180
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Service Manual
Philips Domestic Appliances and Personal Care
Published by Philips Domestic Appliances and Personal Care Printed in the Netherlands © Copyright reserved Subject to modification
Shaver
HQ7180
06/10
PRODUCT INFORMATION
General:
- Mains/rechargeable operation
- World-wide automatic voltage selection
- Electronic on/off switch
- Washable
Safety information
- This product meets the requirements regarding
interference suppression on radio and TV.
- After the product has been repaired, it should function
properly and has to meet the safety requirements as
officially laid down at this moment.
TECHNICAL INFORMATION
- Voltage : 100 - 240 Volt / 50 - 60 Hz
- Motor voltage : 1,2 Volt
- Shaving heads : HQ8 - 4222 036 05820
- SAP coding : HQ7180
DISASSEMBLY- AND RE-ASSEMBLY ADVICE
Disassembly:
- Remove shaving unit, to prevent damaging during
repairing.
- Remove the 2 screws (A) out of the hairchamber.
- Remove the hairchamber from the body.
- Remove the 2 screws (B) on the backside of the shaver.
- Remove the cover.
- Remove the side grips.
- Remove the housing by bending the hooks with a
screwdriver.
- Take out the basic body.
REPAIR INSTRUCTION
- No specific issues
OPTIONAL (accessories)
- Car cord : 4222 036 08920
- Pouch : 4222 036 14160