HD7870/80 / HD7870/81
5-12
CALC
On/Off button
Regular LED
Toggle button
Strong LED
Calc LED
1-cup button
2-cup button
Please note, as the appliance is equipped with a
capacitive touch panel as a user interface, special
attention is required to be able to enter several service
modes. The capacitive buttons need 0,5 seconds to
initialize after the mains is connected. During this
timeslot the capacitive buttons must not be touched,
otherwise you will not be able to enter the service
modes.
Service mode
The appliance is equipped with a dedicated service mode.
The service mode enables you to carry out some settings
and tests.
REPAIR INSTRUCTION
Service mode
Only in case of a reset appliance you can check it’s current settings.
When connecting the appliance to the mains, you should see the On/Off light blinking very rapidly
for 0.5 seconds. For convenience the country selection and ME/HE selection are also being displayed.
1-cup button1 & 2-cup button2-cup button
Press the indicated button after connecting the mains
Blinking
Off
Blinking
Off
Blinking
General version
Boiler_empty_flag set
France / Spain version
Country
Selection
ME / HE
Selection
Mid-end
High-end
Sensor
On/Off button
1-cup button
2-cup button
Toggle button
NTC boiler
Water level sensor
-
-
On/Off LED
1-cup LED
2-cup LED
Toggle LED
Descale LED
Regular LED
Strong LED
Memory my cup LED
Button pressed
Button pressed
Button pressed
Button pressed
NTC error
Water present
<always on>
<always on>
Button released
Button released
Button released
Button released
NTC ok
Water low
-
-
LED LED on LED off
Settings
Sensor
&
LED test
Boiler
reset
Mid-End / High-End
Selection
(to enable Personal Coffee
Memory button)
Country Selection
(General / France-Spain)
Off
Settings
Manual pump
calibration
(Volume adjustment)