– 145 – NWA-008845-001 Rev.5.0
32ch1003.fm
To provide Call Forwarding-No Answer with the timer on a station basis set by MAT/CAT, do the follow-
ing programming in addition to the programming for Call Forwarding-No Answer with the timer on a sys-
tem basis. Page 142
[Series 3200 R6.2 software required]
DESCRIPTION DATA
Specify the timing of Call Forwarding-No An-
swer to as per CM41 Y=0>100, 101 or CME6
Y=07, 08.
(1)
(2)
Y=46
X-XXXXXXXX: My Line No.
0: As per CM41 Y=0>100, 101 or CME6
Y=07, 08 NOTE
NOTE: When CME6 Y=07, 08 are set, the timing on a station basis (CME6 Y=07, 08) is effective.
When CME6 Y=07, 08 are not set, the timing on a system basis (CM41 Y=0>100, 101) is
effective.
[Series 3200 R6.2 software required]
Specify the timing of Call Forwarding-No An-
swer for a trunk incoming call.
(1)
(2)
Y=07
X-XXXXXXXX: My Line No.
001-120 : 4-120 seconds
(4 second increments)
NONE : As per CM41 Y=0>100
Specify the timing of Call Forwarding-No An-
swer for an internal call or an assisted call.
(1)
(2)
Y=08
X-XXXXXXXX: My Line No.
001-120 : 4-120 seconds
(4 second increments)
NONE : As per CM41 Y=0>101