Upgrade to a high performing T12 lamp 7
† This lamp is better for the environment because of its
reduced mercury content.All Philips ALTO
®
lamps give you
end-of-life options which can simplify and reduce your lamp
disposal costs depending on your state and local regulations.
Color Nom. Rated Approx.
Product Ordering Nom Package Temp Length Avg. Life Initial Design Lumen
Number Code Watts Qty. (Kelvin) (In.) (Hrs.)
1
Lumens
2
Lumens
3
CRI Maint.
Philips Long Life T12 Fluorescent Lamps
14251-3 F34/CW/RS/EW/LL/ALTO 34 30 4100 48" 24,000 2650 2300 62 88%
14252-1 F34/WW/RS/EW/LL/ALTO 34 30 3000 48" 24,000 2700 2350 53 88%
Philips 800 Series T12 Fluorescent Lamps
14253-9 F34T12/830/EW/ALTO 34 30 3000 48" 20,000 2800 2660 82 93%
14254-7 F34T12/835/EW/ALTO 34 30 3500 48" 20,000 2800 2660 82 93%
14255-4 F34T12/841/EW/ALTO 34 30 4100 48" 20,000 2800 2660 82 93%
14256-2 F34T12/850/EW/ALTO 34 30 5000 48" 20,000 2650 2520 82 93%
14261-2 F40T12/830/ALTO 40 30 3000 48" 20,000 3200 3040 82 95%
14262-0 F40T12/835/ALTO 40 30 3500 48" 20,000 3200 3040 82 95%
14263-8 F40T12/841/ALTO 40 30 4100 48" 20,000 3200 3040 82 95%
14264-6 F40T12/850/ALTO 40 30 5000 48" 20,000 3050 2900 82 95%
Philips Advantage T12 Fluorescent Lamps
14257-0 F34T12/ADV830/EW/ALTO 34 30 3000 48" 24,000 3100 2880 85 93%
14258-8 F34T12/ADV835/EW/ALTO 34 30 3500 48" 24,000 3100 2880 85 93%
14259-6 F34T12/ADV841/EW/ALTO 34 30 4100 48" 24,000 3100 2880 85 93%
14260-4 F34T12/ADV850/EW/ALTO 34 30 5000 48" 24,000 2950 2740 82 93%
26604-9 F40T12/ADV830/ALTO 40 30 3000 48" 24,000 3600 3420 85 95%
26631-2 F40T12/ADV835/ALTO 40 30 3500 48" 24,000 3600 3420 85 95%
26640-3 F40T12/ADV841/ALTO 40 30 4100 48" 24,000 3600 3420 85 95%
26643-7 F40T12/ADV850/ALTO 40 30 5000 48" 24,000 3450 3280 82 95%
1) Average life under specified test conditions with lamps turned off and restarted no more frequently than once every 3 operating hours. Lamp life is appreciably longer if lamps are started less frequently.
2) Approximate initial lumens.The lamp lumen output is based upon lamp performance after 100 hours of operating life, when the output is measured during operation on a reference ballast under standard
laboratory conditions. For expected lamp lumen output, commercial ballast manufacturers can advise the appropriate ballast factor for each of their ballasts when they are informed of the designated lamp.
The ballast factor is a multiplier applied to the designated lamp lumen output.
3) Design lumens are the approximate lamp lumen output at 40% of the lamp’s rated average life.This output is based upon measurements obtained during lamp operation on a reference
ballast under standard laboratory conditions.
GOOD
BETTER
BEST