0x04 ERR_ADDE_FB_ETH_LEN_INVALID
The length of the Ethernet telegram length at the ETH_PDU_LEN output is
larger than the buffer storage unit of the ETH_PDU_DATA input/output.
0x05 ERR_ADDE_FB_ETH_TOO_MANY_RECV_INSTANCES
Too many instances of ETH_RECV function block.
A maximum of ten instances of the function block are permitted.
0x07 ERR_ADDE_FB_ETH_WRONG_ETHTYPE
Incorrect value in the type field (EtherType) of the Ethernet telegram
Table 7-10 Error codes of the "ADD_ERROR" input/output (ERROR output = TRUE)