Operation
Operating Manual PSEN sc ME 5.5 08-17
1005388-EN-01
| 101
10.3.3 Information
Message in the display Error/cause Description/measure
Icon Text
CLEANW2 The font panel of the safety laser
scanner is contaminated and it must
be cleaned to ensure normal opera-
tion.
Clean front panel
DLDNC A new configuration is downloaded.
DLDNF A new firmware version is down-
loaded.
ITLOCK1 OSSD must be restarted Perform a reset of the safety laser
scanner [ 104].
WAITING
CONF
The safety laser scanner waits for a
configuration (e.g. after restoring a
configuration).
Configure the safety laser scanner
(see Configuration of
zones [ 78]).
10.3.4 Log file
A series of events is stored in a log file.
The file is saved in the memory module and synchronously also in the safety laser scanner.
} Events at the safety outputs (violations of the safety zone)
} Events at the inputs for muting and override
} Error
} Updates (firmware, configurations etc.)
} Restoring of configurations
} Current configuration of zone sets
} Exchange of PSEN sc head
The log file is saved in csv format.
The file is saved in the memory module and synchronously also in the safety laser scanner.
An entry is created in the log file for each logged event.
Format of the entries:
<Date> <Time> <Event type <Details on the event>
Example of a mistake:
10-Sep-20 5:24:30 PM;FAULT;FAULT INPUTCF2