Operation
Operating Manual PSEN sc ME 5.5 08-17
1005388-EN-01
| 103
Menu item Menu second
level
Meaning
Device Lifetime (h) The current operating time of PSEN sc ME 5.5
08-17 in hours is displayed
Configuration Configuration-specific displays
Configuration name The name is displayed under which the configura-
tion was saved in PSENscanīConfigurator.
Check sum The check sum is displayed that was created when
saving the configuration.
Last saved date Date of last modification of the project
IP address The first IP address of the PSEN sc ME 5.5 08-17
is displayed.
MAC address The MAC address of the PSEN sc ME 5.5 08-17 is
displayed.
Setting
Menu item Menu second
level
Meaning
Display settings
Rotate The display is rotated.
Reset
PSENscan
Confirming starts a reset of the PSEN sc ME 5.5
08-17.
Exit
Exit menu in the display.
10.5 Restore configuration
Prerequisites
} The memory module is installed correctly.
} The pin assignment must be compatible with the data in the memory module.
} The correct configuration for the application is ready on the memory module.
One of the following conditions must be met.
} The MIB files in PSEN sc ME 5.5 08-17 and in the memory module are different.
} The topologies in PSEN sc ME 5.5 08-17and in the memory module are different.
} The serial numbers saved in PSEN sc ME 5.5 08-17 and in the memory module are dif-
ferent.
Procedure:
1. Switch the safety laser scanner on.
The system checks whether the conditions are met. When the conditions are met,
restoring of the configuration is started.
2. Depending on the type of difference between memory module and PSEN sc ME 5.5
08-17 the restoring of the configuration varies.