Overview
Operating Manual PSEN sc ME 5.5 08-17
1005388-EN-01
| 11
Legend
Status of the OSSD 1/2 Lights up green: No object detected in safety zone
Lights up red: Object detected in safety zone
Not used
Status of the warning
zone 2
off: No object detected in warning zone 2
Lights up yellow: Object detected in warning zone 2
Status of the warning
zone 1
off: No object detected in warning zone 1
Lights up yellow: Object detected in warning zone 1
Locking Lights up yellow and
lights up red:
No object detected in safety zone,
PSEN sc ME 5.5 08-17 waits for manual restart
off and lights up green:
No object detected in safety zone,
PSEN sc ME 5.5 08-17 is ready for operation
off and lights up red:
Object detected in safety zone,
PSEN sc ME 5.5 08-17 in OFF state