CAUTION!
Risk of injury due to insufficient safeguard
Reaching into the opening between safety laser scanner and mounting area
can lead to injuries.
Prevent reaching into the opening by using a suitable safeguard.
5.1.4 Vertical application
A vertical application is given when the safety laser scanner is aligned at an angle of over
±30° with the floor level.
[2]
[3]
[1]
Fig.: Schematic representation of a vertical application on a passage
Legend
[1] Danger zone
[2] Area covered by the laser beam
[3] Safety laser scanner
The following applies for these applications:
S = K * (t
1
+ t
2
) + Z
T
+ Z
R
+ C
S Minimum distance in mm, measured from the start of the protective zone to the
danger source