Project configuration
Operating Manual PSEN sc ME 5.5 08-17
1005388-EN-01
| 46
} Use a muting lamp with an LED lamp and a max. current consumption of 250mA.
} Indicate clearly visible near the protected area that there is no protection when the muting
lamp is lit.
} The muting sensors have to positioned in a way that the muting area cannot be reached
while muting is active.
5.15.2 Muting in two directions
} The muting status occurs
When the signal at the muting input 2 switches to High after the muting input 1 has
also switched to high (or the muting input 1 switches to High after the muting input 2)
and
The delay between the two signal changes is in the configurable area Muting activa-
tion delay [ms]. The max. delay can be configured between 1 and 16 seconds.
} The muting state is ended
When the configured time is reached or
When the signal at one of the two muting inputs switches to low and
the internal delay of max. 30 ms has elapsed.
t
t
1
t
3
t
2
t
4
t
5
Input
Muting 1
Input
Muting 2
Muting
function
At
Off
At
Off
At
Off
Fig.: Timing diagram T muting
Legend
t
1
Delay between Muting 1 and Muting 2 (configurable from 1-16 s)
t
2
Duration of the muting state (max. up to the configurable time exceeded)
t
3
Internal delay before the ending of the muting state (max. 30 ms)
t
4
Delay between Muting 1 and Muting 2 (configurable from 1-16 s)
t
5
Duration of the muting state (max. up to the configurable time exceeded)

Table of Contents