Wiring
Operating Manual PSEN sc ME 5.5 08-17
1005388-EN-01
| 57
6.3 Connector assignment slave unit
The slave unit of the safety laser scanners PSEN sc ME 5.5 08-17 has two 8-pin M12 sock-
ets for connecting to the master unit or to a different slave unit. In PSENscanConfigurator
this configuration also has to be made when creating a new configuration.
} Two hinged 8-pin M12 sockets for connecting to a master unit or a slave unit
– Two inputs at the socket to the master or at an upstream slave unit
– Two outputs at the socket to the master or at an upstream slave unit
– Two connections each for the supply voltage by the master unit and the functional
earth
6.4 Configurable inputs/outputs
When using the 8-pin connection, configurable input/output at PIN 1 can be used for the fol-
lowing functions:
} Warning output
} Muting lamp
When using the 17-pin connection or both male connectors (17- and 8-pin), the configur-
able inputs/outputs at PIN4, 5, 9 and 15 can be used for the following functions:
} Warning output
} Alarms 1 or 2
} Muting lamp
} Status override 1 or 2
} PIN 4 and PIN 15 can be used for OSSD 2
} PIN 5 and PIN 9 can be used for OSSD 3
} For PINs that you do not use as outputs, select No function. Therefore, the configurable
inputs/outputs are free for the configuration as inputs.
6.5 Configurable inputs
Please note:
} PINs you have already used as an output are no longer available in the configuration of
the inputs.
} When using the 8-pin connection, the configurable inputs at PINs 1, 3 and 4 can be used
for the following functions:
– Restart
– Reset
– Restart or reset
– Zone set switching
– Muting 1 and 2
– Dynamic activation of the muting state
– Override