Installation and alignment
Operating Manual PSEN sc ME 5.5 08-17
1005388-EN-01
| 68
90°
[2]
[1]
[4]
[3]
Legend
[1] Adjusting disc for angle of inclination
[2] Set screw for the adjusting disc for angle of inclination
[3] Fixing screws for safety laser scanner
[4] Fine adjustment screws for the incline of the safety laser scanner
5. Insert the safety laser scanner in PSENscbracketPR with the bracket
PSENscbracketH to the top and fix the safety laser scanner with the screws [3] and
[4]. Tighten all four screws to 3 Nm.
max. ± 6°
max. ± 8,5°
Inclination to the top/bottom Inclination to the side (roll)