Installation and alignment
Operating Manual PSEN sc ME 5.5 08-17
1005388-EN-01
| 69
7.6 Installation with angle of inclination setting - holder PSEN sc
bracket P
} The setting of the angle of inclination of the safety laser scanner is not changed when ex-
changing the safety laser scanner.
Prerequisites
} Mounting surface with 2 drill holes, 10mmdeep, distance 73mm horizontally towards
each other for fixing the PSENscbracketPR or PSENscbracketP
} The protective bracket PSENscbracketH must already be fixed at the safety laser scan-
ner (see Installation of the protective bracket PSEN sc bracket H at the safety laser
scanner [ 65]).
Procedure:
[5]
[6]
[1]
[2]
[3]
[3]
[4]
[4]
Legend
[1] Adjusting disc for angle of inclination
[2] Set screw for adjusting disc for angle of inclination
[3] Fixing screws for safety laser scanner
[4] Fine adjustment screws for the incline of the safety laser scanner
[5] PSEN sc bracket P
[6] Fixing screws for fixing to the mounting surface
Procedure:
1. Fix PSENscbracketP with the fixing screws [6] to the mounting surface and tighten
the fixing screws [6] alternately and evenly with 3 Nm.
2. Fix the adjusting disc for angle of inclination [1] with the set screw and washers [2] at
PSENscbracketP or PSENscbracketPR (right or left).
3. Align the middle of the adjusting disc for angle of inclination [1] with the center of the fix-
ing for the safety laser scanner [3] and tighten the set screw for the adjusting disc for
angle of inclination [2] with 2,5 Nm.
7.7 Set the angle of inclination of the safety laser scanner
Procedure:
1. Change the inclination of the safety laser scanner within the permitted range of ±6°.