Installation and alignment
Operating Manual PSEN sc ME 5.5 08-17
1005388-EN-01
| 70
If necessary, loosen the fixing screws for the safety laser scanner [3], the fine adjust-
ment screws for the inclination of the safety laser scanner [4] and the set screw for the
adjusting disc for angle of inclination [2].
max. ± 6°
[2]
[1]
[4]
[3]
Legend
[1] Adjusting disc for angle of inclination
[2] Set screw for adjusting disc for angle of inclination
[3] Fixing screws for safety laser scanner
[4] Fine adjustment screws for the incline of the safety laser scanner
2. Tighten the fixing screws for the safety laser scanner [3] with 3 Nm. Tighten the fine ad-
justment screws for the inclination of the safety laser scanner [4].
3. Tighten the set screw for the adjusting disc for angle of inclination [2] with 2,5 Nm.
7.8 Set the side inclination of the safety laser scanner
Prerequisites
} The bracket PSENscbracketPR has to be installed at the mounting surface.
Procedure:
1. Change the side inclination of the safety laser scanner within the permitted range of
±8.5°.
If required, loosen the roll angle fine adjustment screws [7] (see figure Installation with
setting of angle of inclination/roll angle - bracket PSEN sc bracket P [ 66]).
2. Tighten the roll angle fine adjustment screws [7] (see figure Installation with setting of
angle of inclination/roll angle - bracket PSEN sc bracket P [ 66]) with 2,5 Nm.

Table of Contents