First commissioning
Operating Manual PSEN sc ME 5.5 08-17
1005388-EN-01
| 82
Check the safety function of the safety laser scanner as indicated in
Inspection [ 94].
Each time the test piece enters into the safety zone, the OSSDs must switch to the OFF
state and the status of the OSSDs in the Monitoring work window must show the viola-
tion of the safety zone.
The OSSDs must switch to the OFF state each time the reference point changes bey-
ond the tolerance range, and the status of the OSSDs in the Monitoring work window
must show the changing of the reference points.
Each time the test piece violates the warning zone, this warning zone violation must be
indicated by the status of the warning output in the Monitoring work window.
19. Select Download configuration to device, to transfer the configuration to the device.
Click Accept to activate the downloaded configuration in the connected device and re-
ject the existing configuration on the connected device.
Save the report in PDF format.
Click Reject to reject the downloaded configuration in the connected device and con-
tinue to use the existing configuration on the connected device. The downloaded con-
figuration in the connected device will be deleted.
9.3.2 Example for a 17-pin connection
Settings in PSENscan Configurator for a safety laser scanner with 17‑pin connection: Ver-
tical application with reference outline monitoring, 2 OSSD pairs, 3 zone sets, no warning
output, no muting, alarm for a device error, manual restart for the first safety zone
Prerequisites
} The safety laser scanner is already connected to the 17-pin male connector.
Procedure:
1. From the start page, select Create new configuration.
The window Device selection is displayed with one tab each Online and Overview of
all types.
2. Select the connected device from Overview of all types. Double-click the device.
The device is displayed in the work window and it can be configured.
3. Under Application, select the application VERTICAL and 17-pin connection.
Configuration
You can enter a title for the configuration under Name.
You can enter the name of the person who created the configuration under Author.
You can describe the configuration in detail under Description.
The Configurator Version is entered by the system and cannot be changed.
The Check sum is entered by the system and cannot be changed.
The Creation date is entered by the system and cannot be changed.
Device
You can enter a title for the connected device under Name.
Safety laser scanner arrangement