First commissioning
Operating Manual PSEN sc ME 5.5 08-17
1005388-EN-01
| 95
} Response time and stopping time must fulfil the requirements in Maintaining the safety
distance [ 29].
Ensure that the safety laser scanner's response time and the machine's stopping time ful-
fil the requirements Maintaining the safety distance.
} Intense or flashing light sources in the vicinity
The allowance Z
R
for particularly intense or flashing light sources near the safety laser
scanner (range of +/-5° to the scan level or highly reflective background within a distance
of 2.5 m to the safety zone perimeter) has been considered when calculating the safety
distance (see Distance to intense light sources [ 40]).
} Ambient conditions
Please observe the environmental conditions [ 39].
} Check the safety laser scanner’s front panel.
– Scratched front panel: Exchange the PSEN sc head. [ 107]
– Dirty front panel: Clean the front panel [ 107].
Create backup copy of a configuration
} After successfully checking the installation and configuration of the safety laser scanner,
create a backup copy of the configuration.
Procedure:
} Select Project -> Save.
The dialogue box for saving is opened. Please enter a name for the MIB file.
The MIB file includes all the data for configuration.