Operation
Operating Manual PSEN sc ME 5.5 08-17
1005388-EN-01
| 96
10 Operation
10.1 Display of the monitoring status
Icon Status Description/measure
Valid config-
uration
Configura-
tion not yet
accepted
Device is switched on and ready for
operation
Warning zone has been violated A violation of the warning zone has
been detected. The configured ac-
tion for a violation of the warning
zone has been triggered.
The area of violation is marked out-
side the semicircle with the yellow
beams.
Safety zone has been violated A violation of the safety zone has
been detected. The OSSDs are in
the OFF state.
The area of violation is marked out-
side the semicircle with the red
beams.
Change detected in the reference
outline
A violation of the reference outline
has been detected. The area of
change is marked outside the semi-
circle with the blue beams.
Check the cause for the change and
eliminate the cause or adapt the ref-
erence outline.
10.2 Display during normal operation
Message in the display Status Description/measure
Icon Text
CLEANW2 The front panel must be cleaned Decommission the safety laser
scanner.
Clean the safety laser scanner’s
front panel [ 106].
DLDNC Download of a configuration or a re-
port
A configuration or a report is
downloaded.