EasyManua.ls Logo

Pilz PZE X4V User Manual

Pilz PZE X4V
23 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
PZE X4V
Operating Manual-1003200-EN-12
} Safety relays
Question and Answer IconNeed help?

Do you have a question about the Pilz PZE X4V and is the answer not in the manual?

Pilz PZE X4V Specifications

General IconGeneral
BrandPilz
ModelPZE X4V
CategoryOther
LanguageEnglish

Summary

Safety Information and Guidelines

Intended Use of the Module

Details the product's compliance with EN standards and its function as an expansion module.

Safety Regulations and Compliance

Outlines requirements for safety assessment and adherence to relevant regulations.

Safety Assessment Procedure

Emphasizes the need for a safety assessment in accordance with the Machinery Directive.

Use of Qualified Personnel

Specifies that only competent persons should assemble, install, and operate the product.

General Safety Precautions

Highlights essential safety conditions and specific notes, such as overvoltage category.

Unit Features Overview

Positive-Guided Relay Outputs

Describes the four safety contacts with delay-on de-energisation functionality.

Key Safety Features

Circuit Expansion and Monitoring

Explains how the module expands circuits and transfers safety functions via feedback loop.

Earth Fault Detection Mechanisms

Describes detection of earth faults in feedback and input circuits.

Function Description and Operation

Input Circuit Closed Procedure

Describes functional procedure when the input circuit is closed, including LED status.

Input Circuit Opened Procedure

Details functional procedure when the input circuit is opened and safety contacts close.

Wiring and Connection Procedures

Preparing for Operation

Operational Procedures and Checks

Safety Contact Verification Process

Details the procedure to verify safety contacts open correctly using base unit outputs.

Periodic Safety Function Checks

Recommends checking safety functions after initial commissioning and plant changes.

Faults and Interference Handling

Unit Start-up Fault Conditions

Lists faults preventing unit startup, including contact malfunction and open circuits.

Electrical Data Specifications

Supply Voltage and Tolerance

Details the 24 V DC supply voltage and its tolerance range.

Input Circuit Parameters

Lists input circuit voltage, current, and maximum cable resistance (Rlmax).

Relay Output Contact Details

Specifies number of safety contacts, short circuit current (IK), and utilisation category.

Relay Output Performance Specifications

AC/DC Load Ratings for Safety Contacts

Details current and power ratings for AC1, DC1, and AC15 load types.

Safety Characteristic Data

Safety Contact Performance Levels

Details PL (Performance Level) and Category for safety contacts.

SIL and PFH Values

Provides SIL CL and PFH values for safety integrity.

Mission Time and Retest Intervals

Specifies mission time (Tm) and retest intervals for safety functions.

Supplementary Data and Service Life

Service Life Graphs

Illustrates relay output service life based on switching current and load type.