HUNTER-PRO 32 Intruder Alarm System - Installation Manual
20
Classical Application for Example B
Storage floorpartition 4
Store (floor) partition 1
Production floor partition 2
Management floorpartition 3
Keypad 1
Keypad 4
Keypad 3
Keypad 2
A company building is divided into 4 departments that have different entrances
and different working hours:
Each of the departments has its own individual keypad. Accordingly:
Keypad 1 is allocated to partition 1 (store floor)
Keypad 2 is allocated to partition 2 (production floor)
Keypad 3 is allocated to partition 3 (management floor)
Keypad 4 is allocated to partition 4 (storage floor)
In addition, partition 1 can be controlled by a single user code or several user
codes (vital for foreman and storage workers, for example).
NOTE:
You can also limit disarming hours and other authorizations for each user.