HUNTER-PRO 32 Intruder Alarm System - Installation Manual
25
(one or two) is defined as a general rule for all the zones (refer to section.
5.3.1).
3.2.2 Connecting Detector without using EOL resistor
Connect a detector with NC output (for example, Defender-2K) without EOL
resistor according to the below diagrams.
There are several options to connect the tamper outputs from the detectors:
serial connection that can be connected to the tamper input in the control
panel, or to a zone that is defined to as 88 “24 hours”.
The Tamper can also be connected in serial to the relay output of the detector.
NOTE:
When connecting NO detector, make sure the zone input is configured NO as
well (refer to section. 5.3.1).
+-
JP2
JP1
PIR1
TAMPER NC RELAY NC
Zone
Common
Common
Tamper Zone
3.2.3
Connecting Detector using one EOL resistor
Connect an NC detector (for example, DEFENDER) with one EOL resistor
according to the below diagrams.
The tamper can be connected to the control panel’s tamper output, or a “24
hour” zone.
NOTE:
When connecting NO detector, make sure the zone input is configured NO as
well (refer to section. 5.3.1). For tamper configuration: section 5.6).
Connecting EOL resistor to NC PIR Detector