One EOL resistor
connected to a NC
detector
One EOL resistor in serial
to the relay and the
TAMPER
Separate connections for
the relay and the TAMPER;
each with a dedicated EOL
resistor
3.2.4 Connecting Detector using two EOL resistors
Connect a detector with NC output (for example, Defender-2K) with two EOL
resistors according to the below diagrams.
If you use the NO output from the detector then the zone should be configured
as such (for zone configuration, refer to sections 5.3.1; For tamper
configurations, refer to section 5.6.)
Two EOL resistors with a Normally Closed (NC) PIR
TAMPER
Zone
10K ¼W
PIR (NC)
13K ¼W
(-)
+-
JP2
JP1
PIR1
TAMPER NC RELAY NC
Common
13K ¼W
10K ¼W
Zone
2 EOL resistors with a NC output 2 EOL resistors connected to a TAMPER in
serial connection to a NC output
Two EOL resistors with a Normally Open (NO) PIR