HUNTER-PRO 32 Intruder Alarm System - Installation Manual
29
I/O-8-External Expender 3
)1( )1(
32-25
)2( )2( )2(
RC-PRO-Wireless
Expansion
)1( )1( )1(
32-25
)3(
32-17 24-9
Table 1-Zone Numeration in HUNTER-PRO 32
) 1( Cannot be installed in the system since quantity of zones exceeds 32
)2( Not installed in the system
)3( It is possible to use only 8 out of the receiver’s 16 wireless zones
3.3.1 EXP-LOCAL: Local Expansion
An 8-zone expansion card, used for connecting 8 additional wired zones. These
zones are identical to those of the HUNTER-PRO 32, and shall always be
programmed in the system as zones 9 to 16.
NOTE:
Disconnect all of the system’s power sources before installing the expansion
card.
To connect the EXP-LOCAL:
1. Use the two supplied screws to connect the card to the control panel’s box
2. Use the supplied Flat Cable to connect between the card and JP3 (see
Drawing 4).
3. To configure the Expansion Card refer to “Expansion Outputs” section 3.9.