HUNTER-PRO 32 Intruder Alarm System - Installation Manual
33
Key
Key (NC)
(-)
Z5 Z6 Z7 Z8
-
+
KEY
-
S1 S2
SIREN
F3
F2
Control Panel
Drawing 7-Connecting spring key to control panel
3.5 TMPR1 and TMPR2
These inputs are used to monitor the control panel box, detector housings and
siren cases using tamper switches. This input can also be utilized for panic
buttons, temperature sensors with dry contact outputs and more.
Connect the tamper switch to the input, TMPR1 or TMPR2 and the ground (–).
A 10 kW EOL resistor at the terminal input on the PCB. The EOL provides a
short/disconnect indication since the tamper switches are of the NO type.
NOTE:
Default programming is that both TAMPER inputs are enabled and without
EOL. Refer to the “System Configuration” screen in order to change the
defaults (section 5.6).
TMPR
2
TMPR
1
ON/
OFF
ALARM
KEYPAD
-
SMOKE
-
+ OUT
JP
5
Z5 Z6 Z7 Z8
-
+
KEY
-
S1 S2
SIREN
F3
TAMPER switch
Control Panel
IN
F2
Drawing 8-Connecting tamper to control-panel
3.6 Connecting Sirens
Three siren types can be connected to HUNTER-PRO 32