HUNTER-PRO 32 Intruder Alarm System - Installation Manual
36
NOTE:
If Relay Time is programmed as zero, the relay is constantly activated until
Relay Code is entered or the system is switched OFF.
3.8 Auxiliary Outputs:
ON/OFF
(AUX1)
ALARM
(AUX2)
HUNTER-PRO 32 has two outputs for general use. In “General Parameter”
screen (see section 5.6) the default is that AUX1 is designated for
arming/disarming the system and AUX2 for the keypad’s buzzer.
AUX1 switches (-) when activating system (ON/OFF output) system default
AUX2 switches (-) at time of alarm (ALARM output) system default
Also, these outputs can be allocated for further uses when the zone’s
responses are configured (see section 5.3.4).
IMPORTANT!
Configuring ON/OFF and/or ALARM in one of the zone responses cancels the
configuration in General Parameters screen.
3.9 Expansion Outputs: OUT-1000
It is possible to add up to 8 outputs activated by an alarm for peripheral
devices such as CCTV, alarm triggered lights, etc.
IMPORTANT!
Disconnect any of the system’s power sources before installing the card
Follow the drawing 8 in order to connect the card to the control panel: