HUNTER-PRO 32 Intruder Alarm System - Installation Manual
39
Important!
If keypad supervision is not needed,
The number of keypads connected to the system is not to be configured
The keypads’ ID need be set as zero (0).
Note
Up to 8 keypads can be connected to the system, whether they have
supervision or not.
3.12
Telephone Line and Devices
It is preferable that the PSTN line connects directly to the LINE input so that
the system will be the first device connected to the line. This type of
connection will prevent disconnecting the system and enable efficient “line
snapping”.
The rest of the telephone devices (telephone, answering machine, etc.) need
be connected to the SET terminal block in order to enable “line snapping” (i.e.
at time of an alarm these devices will be disconnected and the system will be
able to dial even if the line is busy by one of them).
TMPR
2
TMPR
1
ON/
OFF
ALARM
OUT
F4
T1
TELEPHONE OUTLET
Control Panel
LINE SET
AUD
CONT
IN
OUT
Drawing 14- Connecting telephone line to control panel
IMPORTANT!
A fax machine or a modem can only be connected to SET input if “line
snapping” is enabled.