HUNTER-PRO 32 Intruder Alarm System - Installation Manual
55
ENTR
Remote Expanders
0
In this screen you program the amount of remote expenders (I/O-8) installed
on the keypad’s BUS.
It is possible to install up to three expenders in the system.
NOTES:
If a parameter larger than possible is entered into the system, the system
will reset the parameter.
If the EXP-LOCAL expender is installed, only two more expenders can be
added to the system.
5.2.3 Wireless Expender
ENTR
1
Wireless Expand.
ENTER/NEXT/END
ENTR
NEXT
Sys Installation
ENTER/NEXT/END
x2
Wireless Expand.
0 Zones
9
In this screen you program the amount of wireless zones connected, if a
wireless expender is installed in the system. It is possible to program up to 16
zones.
IMPORTANT!
The wireless zones are programmed only after the other expenders. Meaning:
If there are no other expenders, the wireless zones are 9 to 24.
If there is a local expender, the wireless zones are 17 to 32.
If all the ‘wire expenders’ possible are installed, it is not possible to install
wireless zones (for the zone numeration table, refer to section 3.3).
After programming the number of wireless zones in the system, you need to
program the Jam Signal Level and the duration of time for the Supervision
signals (i.e. “life signals”).
Block Level: 0
Supervision: 0