HUNTER-PRO 32 Intruder Alarm System - Installation Manual
56
Jam Signal Level:
The receiver’s frequency minimum signal level (RSSI) to
which the system will respond. There are 11 levels from
which you can choose, rating from “0” to “10”. “0”
means this feature is neutralized and from “1” until “10”
there is s gradual rise.
NOTE:
Jam Signal Level has to appear for at least one minute before the system can
respond to it.
Supervision Signal:
The duration of time (in hours) in which the Control
Panel expects to get a Supervision signal from each of
the wireless detectors.
IMPORTANT!
Since wireless PIR detectors transmit a Supervision signal approximately every
three hours, the duration of time between each signal has to be longer than 3
hours.
5.2.4 Keypads
ENTR
1
Keypads Setup
ENTER/NEXT/END
ENTR
NEXT X3
Keypads Setup
0 Keypads
Sys Installation
ENTER/NEXT/END
9
In this screen the total number of keypads connected to the system is
programmed (remember there cannot be more than 8 keypads). For example,
entering this data is required when a TAMPER switch is used to protect the
keypads.
5.2.5 Keypads Partitions
If a number of keypads were configured in the system, it is possible to allocate
them to partitions:
Part. for RKD 2
-++--------++---
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32